$4,669.99 SKU SWP-NV25B7FE1T

V-Flow Pump NV25-7S

$4,669.99

25GPM / Seven-stage hydraulic design for high-pressure applications (up to 362 PSI).

  • Shop Pay
  • Apple Pay
  • Google Pay
  • Visa
  • Mastercard
  • American Express
  • Description
    • 25GPM / Seven-stage hydraulic design for high-pressure applications (up to 362 PSI).
    • 304 stainless steel construction for corrosion resistance and long service life.
    • Maintenance-free cartridge mechanical seals for simplified servicing.
    • Vertical Design to save space in mechanical rooms or tight installations.
    • Versatile Applications including reverse osmosis, water treatment, irrigation, and industrial water boosting.
    Read the full description
  • Fast shipping, details
  • Lifetime support, details
  • Made in USA
Shipping

Free shipping on orders over $150

Residential addresses in the lower 48 US states. Excludes business addresses, commercial and industrial systems (which ship by freight), and filter media sold by the bag or cubic foot.

Shipping for this item is calculated at checkout.

Order by 3:00 PM Eastern on a business day and most filters, cartridges and smaller items leave our facility that same day. Standard residential systems ship within 1 to 2 business days, and whole house, custom and specialty systems typically within 3. So far in 2026, 95% of our orders have shipped within one business day and 99% within five (based on an internal review of our order records).

Once shipped, standard delivery typically arrives in 3 days to the Southeast, Northeast and Southwest, and in 4 days to the Midwest and the West. Need it sooner? UPS 2nd Day Air and Next Day Air are available at checkout for eligible products. Systems that ship by freight can take longer and may need a delivery appointment.

Lifetime support

Our team answers questions about products, orders, installation, troubleshooting and replacement parts.

Phone: (770) 951-5600 or (800) 934-0051

Email: help@crystolquest.shop. Typical responses within 24 hours (M-F).

Live chat during business hours

Hours: Monday to Friday, 9:00 AM to 5:00 PM Eastern. We observe U.S. federal holidays.

25GPM / Seven-stage hydraulic design for high-pressure applications (up to 362 PSI).

Read more
SKU SWP-NV25B7FE1T
Edit selections

Overview

Product Description

The SWP V-Flow Pump NV25-7S Vertical Pump is a compact and efficient multistage booster pump designed for high-demand industrial, commercial, and agricultural applications. Its vertical, in-line design saves space while providing exceptional reliability and performance.

Equipped with a 2 HP motor, the V-Flow Pump NV25-7S delivers a flow rate of up to 25 GPM and can handle pressures up to 362 PSI. Constructed with durable 304 stainless steel components, this pump ensures corrosion resistance and long-lasting operation in a wide range of environments. Maintenance-free cartridge mechanical seals and ANSI standard flanged connections make installation and servicing simple and efficient.

Certified to meet NSF/ANSI 61 and 372 standards, this pump is ideal for applications such as reverse osmosis, water boosting, filtration systems, hot and cold water circulation, and irrigation.

Specifications

V-Flow Pump NV25-7S

Vertical Multistage Booster Pump, 304 Stainless Steel

Technical Specifications
Rated Flow 25 GPM
Stages 7
Max Working Pressure 362 PSI
Max Inlet Pressure 150 PSI
Motor Power 2 HP
Motor Phase / Frequency 1PH / 60Hz
Motor Frame 56C
Motor Enclosure T - TEFC
Pump Length (Flanged) 17.40 in
Weight (Flanged) 45 lbs

Parts & Components

Construction & Design Features (304 Stainless Steel Model)

Component Material (304 SS Models)
Motor Bracket Cast Iron
Pump Head 304 Stainless Steel
Impeller 304 Stainless Steel
Diffuser 304 Stainless Steel
Neck Ring Teflon
Shaft 431 Stainless Steel
Casing 304 Stainless Steel
O-Ring EPDM
Pump Base 304 Stainless Steel
Base Plate Cast Iron
Mechanical Seal Silicon Carbide/Silicon Carbide/EPDM

Installation Instructions

Installation Manual

Installation Instructions for V-Flow Pump NV25-7S Vertical Pump

  1. Preparation:
    • Inspect the pump and motor for any visible damage during shipping. Report any damage to the carrier or dealer.
    • Ensure the installation site is level, stable, and provides adequate ventilation for motor cooling and servicing.
    • Verify that the pump model matches the system specifications and intended application.
  2. Mounting the Pump:
    • Secure the pump base to a solid, flat surface to prevent vibrations during operation.
    • Align and support the suction and discharge piping to avoid excessive strain on the pump.
    • Install isolation valves on both the suction and discharge sides for easier maintenance and servicing.
  3. Piping Connections:
    • Ensure piping matches the pump’s 1.5" ANSI 150# flanged connections.
    • Install proper gaskets to prevent leaks, ensuring they do not obstruct flow.
    • Remove protective covers or caps from the flanges before installation.
    • For hot water systems, include a bleed valve in the discharge line to relieve pressure during maintenance.
  4. Electrical Connection:
    • Have a certified electrician verify that the electrical supply matches the motor’s specifications (2 HP).
    • Ensure proper motor wiring and confirm counterclockwise rotation when viewed from the motor’s rear.
    • If rotation is incorrect on a three-phase motor, reverse any two leads to correct it.
  5. Priming the Pump:
    • Remove the fill plug and use a funnel to fill the pump casing with water.
    • Open the vent plug to allow air to escape as the pump fills with water.
    • Re-seal the vent plug and fill plug once a steady stream of water flows from the vent.
  6. Initial Testing:
    • Open the suction valve fully and partially open the discharge valve.
    • Apply power to the motor and monitor for smooth operation without noise or vibration.
    • Gradually open the discharge valve to achieve desired operating conditions.
  7. Safety Precautions:
    • Never operate the pump without water to avoid damage to internal components.
    • Replace coupling guards after installation to prevent injuries.
    • Ensure the pump is properly grounded and all connections are secure before starting.